Cisco support status lookup by serial number. Ask Question 1. Many vendors allow you to look at the support status of a device with no information besides a serial number. Does this exist for Cisco products? Cisco licensing warranty. The 'Cisco Service Contract Center' will let you look up support status by serial number. Simon is right on with his solution. I wouldn't say it's /never/ correct in IOS but the only way to do this 100% accurately is to physically get the serial number off the box and then enter it in snmp-server chassis-id like Simon has pointed out. You can NEVER trust the information from IOS or RME or anywhere else. I really wanted to make this “10 Ways To Find The Serial Number of Your Cisco Router” but I honestly couldn’t think of two more ways to grab the serial number of a router. I’m certain there are probably a couple more obscure ways to do this, but I haven’t bothered scouring the IOS commands in search of alternative means of determining.
Recently, I was doing a true up of our Cisco SmartNet contract, and had to get the serial numbers from all of the Cisco devices on the network. Rather than access each device manually, I wrote a bash script that would get the serial numbers via the SNMP ENTITY table. To use the script, you will need:
The command syntax is (which you can also get from running “./getserial.sh -–help” ) – ./getserial.sh [community] [list] [report_file.csv] Parameters are as follows- community – RO community string for devices The script – #!/bin/bash # Help prompt #Location of ENTITY-MIB # Set VARs # Create CSV file and set header # Loop through devices in list # Get hostname from device # Add hostname and device name to csv # Echo status to stdout # Querry ENTITY table on device cut only entPhysicalDescr, entPhysicalClass, entPhysicalSerialNum, entPhysicalModelName # Get line numbers that only have an entry in entPhysicalSerialNum column and input into var LINES # Loop through line numbers in var LINES. Echo TABLE into sed and grab lines from var LINES. # Add line between devices in csv echo -e “nSNMP Qeuries Completed.n” The output file will look like this (with serial numbers masked) – Device Description,Device Type,Serial Number,Model Number,Other firewall1.yourdomain.com switch2.yourdomain.com router1.yourdomain.com nexusswitch1.yourdomain.com You can then open the file up with any application that can parse a CSV, such as Microsoft Excel. For some reason, Cisco router chassis’, Nexus switches, and most SFPs don’t follow the MIB. Since they put serial and model numbers in the entPhysicalAlias column instead of entPhysicalSerialNum, you will find them in the “Other” field of the CSV. ![]() This chapterdescribes how to install and connect Cisco 4000 Series IntegratedServices Routers (ISRs) to LAN, WAN, and Voice networks. Thefollowing sections provide technical details. WarningTo see translations of the warnings that appear in this publication, see the Regulatory Compliance and Safety Information for the Cisco 4000 Series ISRsdocument.Only trained and qualified personnel should be allowed toinstall, replace, or service this equipment. Statement 1030 Warning This unit might have more than one power supply connection. Allconnections must be removed to de-energize the unit. Statement1028 Warning Blank faceplates and cover panels serve three important functions:they prevent exposure to hazardous voltages and currents inside thechassis; they contain electromagnetic interference (EMI) that mightdisrupt other equipment; and they direct the flow of cooling airthrough the chassis. Do not operate the system unless all cards,faceplates, front covers, and rear covers are in place. Statement1029 Warning Hazardous network voltages are present in WAN ports regardless ofwhether power to the unit is OFF or ON. To avoid electric shock,use caution when working near WAN ports. When detaching cables,detach the end away from the unit first. Statement 1026 Warning This equipment must be grounded. Never defeat the ground conductoror operate the equipment in the absence of a suitably installedground conductor. Contact the appropriate electrical inspectionauthority or an electrician if you are uncertain that suitablegrounding is available. Statement 1024 Warning Before opening the unit, disconnect the telephone-network cables toavoid contact with telephone-network voltages. Statement 1041 Warning Donot use this product near water; for example, near a bath tub, washbowl, kitchen sink or laundry tub, in a wet basement, or near aswimming pool. Statement 1035 Warning Never install telephone jacks in wet locations unless the jack isspecifically designed for wet locations. Statement 1036 Warning Never touch uninsulated telephone wires or terminals unless thetelephone line has been disconnected at the network interface.Statement 1037 Warning Avoid using a telephone (other than a cordless type) during anelectrical storm. There may be a remote risk of electric shock fromlightning. Statement 1038 Warning Toreport a gas leak, do not use a telephone in the vicinity of theleak. Statement 1039 WarningThis unit is intended for installationin restricted access areas. A restricted access area can beaccessed only through the use of a special tool, lock and key, orother means of security. Statement 1017 WarningBlank faceplates and cover panels serve three important functions: they prevent exposure to hazardous voltages and currents inside the chassis; they contain electromagnetic interference (EMI) that might disrupt other equipment; and they direct the flow of cooling air through the chassis. Do not operate the system unless all cards, faceplates, front covers, and rear covers are in place. Warning Thecovers are an integral part of the safety design of the product. Donot operate the unit without the covers installed. Statement1077 Before YouBegin![]() Before installingand connecting a Cisco 4000 Series Integrated Services Router, readthe safety warnings and gather the following tools andequipment.
– To installor remove modules – To removethe cover, if you are upgrading memory or other components
– AWG 6 (13mm) wire for NEBS-compliant chassis grounding – AWG 14 (2mm) or larger wire for NEC-compliant chassis grounding – AWG 18 (1mm) or larger wire for EN/IEC 60950-compliant chassis grounding
In addition,depending on the type of modules you plan to use, you might needthe following equipment to connect a port to an externalnetwork:
Note Formore information on cable specifications, see the Cisco Modular Access Router Cable Specifications document at cisco.com.
Also, you need tohave access to the following: CLI ConsoleAccess Use the USB orRJ-45 console port on the router to access the Cisco InternetOperating System (IOS-XE) command line interface (CLI) on therouter and perform configuration tasks. A terminal emulationprogram is required to establish communication between the routerand a PC. See the “Connect to Console Terminal or Modem” section forinstructions. Note AMicrosoft Windows USB driver must be installed before you establishphysical connectivity between the router and the PC. Slot and PortNumbers The routers havebuilt in ports and new slots. The new slots accommodate new modulesand interface cards; SM-Xs, NIMs, ISCs, PVDM4s, and the CiscoE-Series Server modules. See the “Slots, Subslots (Bay), Ports, and Interfaces in Cisco 4000 SeriesISRs” section for slot and port numbering. SoftwareLicenses To installfeatures on the router, you must purchase a software package. Seethe “Licensing” section of the Software Configuration Guide for the Cisco 4400 and Cisco 4300 Series ISRs. Unpack the RouterDo not unpack therouter until you are ready to install it. If the final installationsite is not ready as yet, keep the chassis in its shippingcontainer to prevent accidental damage. When you are ready toinstall the router, proceed with unpacking it. The router,accessory kit, publications, and any optional equipment you orderedmay be shipped in more than one container. When you unpack thecontainers, check the packing list toensure that you received all of the items on the list. Install the RouterIf you need to install Network Interface Modules(NIMs), Service Modules (SMs), and Field-Replaceable Units (FRUs),you can install them either before or after you install the router.Ideally, you install modules when you have the best access to theback panel of the router. Internal modules and FRUs, such as SMs,NIMs or Packet Voice Digital Signal Processor Module (PVDM4s),Compact Flash Cards, and fan trays should be installed beforerack-mounting. You can installthe Cisco 4000 Series Integrated Services Routers in one of thefollowing ways:
Warning Before working on a system that has an On/Off switch, turn OFF thepower and unplug the power cord. Statement 1.
Caution Toprevent damage to the chassis, never attempt to lift or tilt thechassis by holding it by the plastic panel on the front. Alwayshold the chassis by the sides of the metal body.
Set Chassis on DesktopYou can place therouter on a desktop, bench top, orshelf. Note Donot set the chassis in an area where high acoustic noise can be anissue. Warning Toprevent personal injury or damage to the chassis, never attempt tolift or tilt the chassis using the handles on modules (such aspower supplies, fans, or cards); these types of handles are notdesigned to support the weight of the unit. Statement 1032.
Caution Donot place anything on top of the router that weighs more than 10pounds (4.5 kg), and do not stack routers on a desktop. Excessivedistributed weight of more than 10 pounds, or pound point load of
10 pounds on top could damage the chassis.
Caution Yourchassis installation must allow unrestricted airflow for chassiscooling. For placing the router on a desktop, keep at least 1 inch(2.54 cm) of clear space beside the cooling inlet and exhaustvents.
After the routeris installed, you must connect the chassis to a reliable earthground. For the chassis ground connection procedures, see the“Chassis Grounding” section. Attach Chassis toWall or Mount Chassis in RackThe tasks that youperform for attaching the router chassis to the wall or formounting it in a rack are based on the specific model of the Cisco4000 Series Integrated Service Router. See the relevantinstallation sub-section for your specific router in the Cisco 4000Series ISRs: Install Cisco 4400 or 4300 ISRThis sectiondescribes the installation procedure that is common for all Cisco4400 and 4300 Series ISRs. Note Note that for illustration purposes, we have used images of Cisco4400 Series ISRs in all figures. Attach Cisco 4400or 4300 ISR Chassis to WallTo attach Cisco4400 or 4300 ISR: Step 1 Attach the wall-mounting brackets to the router chassis asshown in Figure 3-1 using the four PHMS screws and the plastic spacersprovided for each bracket. Figure 3-1 Bracket Installation for Wall Mounting (Cisco4431 ISR shown)
Caution Donot over-torque the screws. The recommended torque is 15 to 18inch-lb (1.7 to 2.0 N-m).
Note Toattach to a wall stud, each bracket requires one number-10 woodscrews (round- or pan-head) with number-10 washers, or twonumber-10 washer-head screws. The screws must be long enough topenetrate at least 1.5 inches (38.1 mm) into the supporting wood ormetal wall stud. Note Forhollow-wall mounting, each bracket requires two wall anchors withwashers. Wall anchors and washers must be size number 10. Route thecables so that they do not put a strain on the connectors ormounting hardware.
Caution Yourchassis installation must allow unrestricted airflow for chassiscooling.
Step 2 Attach the router to the wall using the brackets. Noteif you prefer, you can also install itdiagonally using the other two sides. Download torrent on ios 9 3. After the routeris installed, you must connect the chassis to a reliable earthground. For the chassis ground connection procedures, see the“Chassis Grounding” section. Mount Cisco 4400 or 4300 ISR Chassis in RackWarningIf the rack is provided with stabilizing devices, install the stabilizers before mounting or servicing the unit in the rack. Statement1006 Warning This equipment must be grounded. Never defeat the ground conductoror operate the equipment in the absence of a suitably installedground conductor. Contact the appropriate electrical inspectionauthority or an electrician if you are uncertain that suitablegrounding is available. Statement 1024 Warning Toprevent the system from overheating, do not operate it in an areathat exceeds the maximum recommended ambient temperature of: 40degrees C. Statement 1047 Cisco 4000 SeriesISRs can be installed in 19-inch (48.26-cm) EIA and 23-inch(58.42-cm) Southwestern Bell Corporation (SBC) racks. Cisco 4000Series ISRs can also be mounted in a 600-mm ETSI rack. Use thestandard brackets shipped with the router for mounting the chassisin a 19-inch EIA rack; you can order optional larger brackets formounting the chassis in a 23-inch SBC rack. You can mount therouter in the following ways:
Step 1 Attach the mounting brackets to the router chassis as shownin Figure 3-2 through Figure 3-5, using the screws provided.
Caution Donot over-torque the screws. The recommended torque is 15 to 18inch-lb (1.7 to 2.0 N-m).
Attach the secondbracket to the opposite side of the chassis. Use a number-2Phillips screwdriver to install the number-8 bracket screws.
Caution Yourchassis installation must allow unrestricted airflow for chassiscooling.
Figure 3-2 Bracket Installation for Front Mounting (Cisco4451-X ISR shown)
Figure 3-3 Bracket Installation for Center-Front Mounting (Cisco 4451-X ISRshown)
Step 2 Usethe screws provided with the rack to install the chassis in therack. (See Figure 3-4 and Figure 3-6.) For both the19-inch EIA brackets and the 23-inch SBC brackets, start the lowerpair of screws first, and rest the brackets on the lower screwswhile you insert the upper pair of screws. Tip The screwslots in the brackets are spaced to line up with every second pair of screw holes in the rack. Assimil - perfectionnement allemand - using german download torrent pdf. When thecorrect screw holes are used, the small threaded holes in thebrackets line up with unused screw holes in the rack. If the smallholes do not line up with the rack holes, you must raise or lowerthe brackets to the next rack hole.
Warning Toprevent personal injury or damage to the chassis, never attempt tolift or tilt the chassis using the handles on modules (such aspower supplies, fans, or cards); these types of handles are notdesigned to support the weight of the unit. Statement 1032
Caution Besure to leave space above and below each router in a rack to allowfor cooling air circulation.
Figure 3-4 Bracket Installation for Back Mounting (Cisco4451-X ISR shown) Figure 3-5 Bracket Installation for Center-Back Mounting(Cisco 4451-X ISR shown) Figure3-6 shows a typical installation in a rack. Figure 3-6 Mounting the Chassis in a Rack (Typical) Figure3-7 shows an installation with a chassis rear-forward. Figure 3-7 Mounting the Chassis in a Rack, Rear Forward (Cisco 4451-XISR shown) After the routeris installed, you must connect the chassis to a reliable earthground. For the chassis ground connection procedures, see the“Chassis Grounding” section. Install Cisco 4200 Series ISRThis sectiondescribes the installation procedure that is common for all Cisco4200 Series ISRs. Note Note that for illustration purposes, we have used images of Cisco4221 ISR in all figures. Attach Cisco 4200ISR Chassis to WallStep 1 Attach the wall-mounting brackets to the router chassis asshown in Step 2 using the four PHMS screws and the plastic spacersprovided for each bracket. Figure 3-8 Bracket Installation for Wall Mounting (Cisco 4221 ISR shown)
Note Donot over-torque the screws. The recommended torque is 15 to 18inch-lb (1.7 to 2.0 N-m). Note Toattach to a wall stud, each bracket requires one number-10 woodscrews (round- or pan-head) with number-10 washers, or twonumber-10 washer-head screws. The screws must be long enough topenetrate at least 1.5 inches (38.1 mm) into the supporting wood ormetal wall stud. Note Forhollow-wall mounting, each bracket requires two wall anchors withwashers. Wall anchors and washers must be size number 10. Route thecables so that they do not put a strain on the connectors ormounting hardware Note Your chassis installation must allow unrestricted airflow forchassis cooling. Step 2 Attach the router to the wall using thebrackets. After the routeris installed, you must connect the chassis to a reliable earthground. For the chassis ground connection procedures, see the“Chassis Grounding” section. Mount Cisco 4200ISR Chassis in RackStep 1 Attach the brackets to the router chassis (towards thefront or back) as shown in Figure 3-10. Figure 3-9 Bracket Installation for Front Mounting (Cisco 4221 ISR shown)
Step 2 Usethe screws provided with the rack to install the chassis in therack. (See Figure 3-10.) Figure 3-10Bracket Installation forBack Mounting
Warning Toprevent personal injury or damage to the chassis, never attempt tolift or tilt the chassis using the handles on modules (such aspower supplies, fans, or cards); these types of handles are notdesigned to support the weight of the unit. Statement 1032
Caution Besure to leave space above and below each router in a rack to allowfor cooling air circulation.
After the routeris installed, you must connect the chassis to a reliable earthground. For the chassis ground connection procedures, see the“Chassis Grounding” section. Mount Cisco 4200ISR Chassis in Rack with AC Power UnitStep 1 Attach the brackets to the router chassis (towards the leftor right) as shown in Figure 3-11 and Figure 3-12. Figure 3-11AC Power Bracket Installation for Left Mounting(Cisco 4221 ISR shown)
Figure 3-12AC Power Bracket Installation for RightMounting (Cisco 4221 ISR shown)
After the routeris installed, you must connect the chassis to a reliable earthground. For the chassis ground connection procedures, see the“Chassis Grounding” section. Chassis GroundingWarning This equipment must be grounded. Never defeat the ground conductoror operate the equipment in the absence of a suitably installedground conductor. Contact the appropriate electrical inspectionauthority or an electrician if you are uncertain that suitablegrounding is available. Statement 1024 Warning During this procedure, wear grounding wrist straps to avoid ESDdamage to the card. Do not directly touch the backplane with yourhand or any metal tool, you could shock yourself. Statement 94 You must connectthe chassis to a reliable earth ground; the ground wire must beinstalled in accordance with local electrical safety standards.
Note This equipment is suitable for installation in NetworkTelecommunications Facilities and locations where the NEC applies.The equipment is suitable for installation as part of the CommonBonding Network (CBN).
To install theground connection for your router,perform the following steps: Step 1 Strip one end of the ground wire to the length required forthe ground lug or terminal.
Step 2 Crimp the ground wire to the ground lug or ring terminal, using acrimp tool of the appropriate size. Step 3 Attach the ground lug or ring terminal to the chassis as shown inFigure 3-13. For a ground lug, use the two screws with captivelocking washers provided. For a ring terminal, use one of thescrews provided. Tighten the screws to a torque of 8 to 10 in-lb(0.9 to 1.1 N-m). Figure 3-13Chassis GroundConnection on the Router (Cisco 4451-X ISR shown) Chassis Step 4 Connect the other end of the ground wire to a known reliable earthground point at your site. Connect PowerThis sectionexplains how to connect AC power tothe router. Warning Read the installation instructions before connecting the system tothe power source. Statement 1004 Warning This unit might have more than one power supply connection. Allconnections must be removed to de-energize the unit. Statement1028 Warning Only trained and qualified personnel should be allowed to install,replace, or service this equipment. Statement 1030 Note Theinstallation must comply with all required electrical codesapplicable at the installation site. Warning When installing the product, please use the provided or designatedconnection cables/power cables/AC adaptors. Using any othercables/adaptors could cause a malfunction or a fire. ElectricalAppliance and Material Safety Law prohibits the use of UL-certifiedcables (that have the “UL” shown on the code) for any otherelectrical devices than products designated by CISCO. The use ofcables that are certified by Electrical Appliance and MaterialSafety Law (that have “PSE” shown on the code) is not limited toCISCO-designated products. Statement 371. Connect to AC PowerIf your router uses ACpower, connect it to a 15 A, 120 VAC(10 A, 240 VAC) circuit with overcurrent protection. Note Theinput voltage tolerance limits for AC power are 90 and 264 VAC. Note This product requires surge protection to be provided as part ofthe building installation. To comply with the Telcordia GR-1089NEBS standard for electromagnetic compatibility and safety, anexternal surge protective device (SPD) is required at the AC powerservice equipment. Warning ACconnected units must have a permanent ground connection in additionto the power cable ground wire. NEBS-compliant grounding satisfiesthis requirement. Statement 284 Warning This product requires short-circuit (overcurrent) protection, to beprovided as part of the building installation. Install only inaccordance with national and local wiring regulations. Statement1045 Warning This product relies on the building’s installation for short-circuit (overcurrent) protection. Ensurethat the protective device is rated not greater than: Connect to Console Terminal or ModemThe router hasasynchronous serial ports and auxiliary ports. These ports provideadministrative access to the router either locally (with a consoleterminal or a PC) or remotely (with a modem).To configure therouter through the Cisco IOS CLI, you must establish a connectionbetween the router console port and either a terminal or a PC. Use the followingcables and adapters to establish a local or remote connection. Table 3-1 Local and Remote Connections
Connect to Serial Port with Microsoft WindowsNote Install the USB device driver before establishing a physicalconnection between the router and the PC using the USB Consolecable plugged into the USB serial port, otherwise the connectionwill fail. See the “Install Cisco Microsoft Windows USB Device Driver”section. Step 1 Connect the end of the console cable with the RJ-45connector to the light blue console port on the router. Note Youcannot use the USB port and the EIA port concurrently. See “Connect WAN, LAN, and Voice Interfaces” section. When the USBport is used it takes priority over the RJ-45 EIA port. Step 2 Connect the end of the cable with the DB-9 connector (or USBType-A) to the terminal or PC. If your terminal or PC has a consoleport that does not accommodate a DB-9 connector, you must providean appropriate adapter for that port. Step 3 Tocommunicate with the router, start a terminal emulator application.This software should be configured with the following parameters:
Figure 3-14Connecting the USB Console Cable to the Router(shown: Cisco ISR 4451-X)
Connect toConsole Port with Mac OS XThis proceduredescribes how to connect a Mac OS X system USB port to the consoleusing the built in OS X Terminal utility. Step 1 Use the Finder to go to Applications > Utilities >Terminal. Step 2 Connect the OS X USB port to the router. Step 3 Enter the following commands to find the OS X USB port number
root:user$ ls -ltr /dev/*usb*
crw-rw-rw- 1 root wheel 9, 66 Apr 1 16:46tty.usbmodem1a21
DT-macbook:dev user$ Step 4 Connect to the USB port with the following command followed by therouter USB port speed To disconnectthe OS X USB console from the Terminal window Enter Ctrl-afollowed by Ctrl- Connect toConsole Port with LinuxThis procedureshows how to connect a Linux system USB port to the console usingthe built in Linux Terminal utility. Step 1 Open the Linux Terminal window. Step 2 Connect the Linux USB port to the router. Step 3 Enter the following commands to find the Linux USB port number
root@usb-suse /dev# ls -ltr *ACM*
root@usb-suse /dev#
Step 4 Connect to the USB port with the following command followed by therouter USB port speed
root@usb-suse /dev# screen /dev/ttyACM09600
To disconnectthe Linux USB console from the Terminal window Enter Ctrl-afollowed by : then quit Install Cisco Microsoft Windows USB Device DriverA USB devicedriver must be installed the first time a Microsoft Windows-basedPC is connected to the USB serial port on the router. This sectioncontains the following topics: Install Cisco Microsoft Windows XP USB DriverThis procedureshows how to install the Microsoft Windows XP USB driver. Before you begin,download the appropriate driver for your router model from theCisco Software Download site, USB Console Software category:http://www.cisco.com/cisco/software/navigator.html?mode=prod Where Do You Find The Serial Number Of A Cisco Isr 4000 Router NumberStep 1 Unzip the file Cisco_usbconsole_driver_X_X.zip (where X isa revision number). Step 2 Ifusing 32-bit Windows XP double-click the file setup.exe from theWindows_32 folder, or if using 64-bit Windows XP double-click thefile setup(x64).exe from the Windows_64 folder. Step 3 TheCisco Virtual Com InstallShield Wizard begins. Click Next. Step 4 TheReady to Install the Program window appears, Click Install. Step 5 TheInstallShield Wizard Completed window appears. Click Finish. Step 6 Connect the USB cable to the PC and router USB console ports. SeeTable 3-1. The EN LED for the USB console port turns green, and within afew moments the Found New Hardware Wizard appears. Following theinstructions to complete the installation of the driver. Step 7 TheUSB console is ready for use. Install Cisco Microsoft Windows 2000 USB DriverThis procedureshows how to install the Microsoft Windows 2000 USB driver. Step 1 Obtain the file Cisco_usbconsole_driver.zip from cisco.comand unzip it. Step 2 Double-click the file setup.exe. Step 3 TheCisco Virtual Com InstallShield Wizard begins. Click Next. Step 4 TheReady to Install the Program window appears, Click Install. Step 5 TheInstallShield Wizard Completed window appears. Click Finish. Step 6 Connect the USB cable to the PC and router USB console ports. SeeTable 3-1. The EN LED for the USB console port turns green, and within afew moments a series of Found New Hardware Wizard windows appear.Following the instructions to complete the installation of thedriver. Step 7 TheUSB console is ready for use. Install Cisco Microsoft Windows Vista USB DriverThis procedureshows how to install the Microsoft Windows Vista USB driver. Step 1 Obtain the file Cisco_usbconsole_driver.zip from cisco.comand unzip it. Step 2 Ifusing 32-bit Windows Vista double-click the file setup.exe from theWindows_32 folder, or if using 64-bit Windows Vista double-clickthe file setup(x64).exe from the Windows_64 folder. Step 3 TheCisco Virtual Com InstallShield Wizard begins. Click Next. Step 4 TheReady to Install the Program window appears, Click Install. Note Ifa User Account Control warning appears, click “Allow - I trust thisprogram..” to proceed. Step 5 TheInstallShield Wizard Completed window appears. Click Finish. Step 6 Connect the USB cable to the PC and router USB console ports. SeeTable 3-1. The EN LED for the USB console port turns green, and within afew moments a pop up window stating “Installing device driversoftware” appears. Following the instructions to complete theinstallation of the driver. Step 7 TheUSB console is ready for use. Uninstall Cisco Microsoft Windows USB DriverThis sectionprovides instructions for how to uninstall the Cisco MicrosoftWindows USB device driver. Uninstall Cisco Microsoft Windows XP and 2000 USBDriverThis procedureshows you how to uninstall both the Microsoft Windows XP and 2000USB driver. The driver can be removed using the Windows Add RemovePrograms utility or the setup.exe program. Using the AddRemove Programs utility Note Disconnect the router console terminal before uninstalling thedriver. Step 1 Click Start > Control Panel > Add or RemovePrograms. Step 2 Scroll to Cisco Virtual Com and click Remove. Step 3 When the Program Maintenance window appears, select the Removeradio button. Click Next. Using theSetup.exe program Note Disconnect the router console terminal before uninstalling thedriver. Step 1 Run the setup.exe for Windows 32-bit or setup(x64).exe forWindows-64bit. Click Next. Step 2 TheInstallShield Wizard for Cisco Virtual Com appears. Click Next. Step 3 When the Program Maintenance window appears, select the Removeradio button. Click Next. Step 4 When the Remove the Program window appears, click Remove. Step 5 When the InstallShield Wizard Completed window appears clickFinish. Uninstall Cisco Microsoft Windows Vista USB DriverThis procedureshows you how to uninstall the Microsoft Windows Vista USBdriver. Note Disconnect the router console terminal before uninstalling thedriver. Step 1 Run the setup.exe for Windows 32-bit or setup(x64).exe forWindows-64bit. Click Next. Step 2 TheInstallShield Wizard for Cisco Virtual Com appears. Click Next. Step 3 When the Program Maintenance window appears, select the Removeradio button. Click Next. Step 4 When the Remove the Program window appears, click Remove. Note Ifa User Account Control warning appears, click “Allow - I trust thisprogram..” to proceed. Step 5 When the InstallShield Wizard Completed window appears clickFinish. Connect WAN, LAN, and VoiceInterfacesThis sectiondescribes how to connect WAN, LAN, andvoice interface cables. It covers the following topics: WarningDo not work on the system or connector disconnect cables during periods of lightning activity.Statement 1001 Warning Toavoid electric shock, do not connect safety extra-low voltage(SELV) circuits to telephone-network voltage (TNV) circuits. LANports contain SELV circuits, and WAN ports contain TNV circuits.Some LAN and WAN ports both use RJ-45 connectors. Use caution whenconnecting cables. Statement 1021 Warning Hazardous network voltages are present in WAN ports regardless ofwhether power to the unit is OFF or ON. To avoid electric shock,use caution when working near WAN ports. When detaching cables,detach the end away from the unit first. Statement 1026
Caution Tocomply with the Telcordia GR-1089 NEBS standard for electromagneticcompatibility and safety, connect Gigabit Ethernet ports usingRJ-45 connectors for shielded twisted pair cable only tointra-building or unexposed wiring or cable. The intra-buildingcable must be shielded and the shield must be grounded at bothends. The intra-building port(s) of the equipment or subassemblymust not be metallically connected to interfaces that connect tothe OSP or its wiring. These interfaces are designed for use asintra-building interfaces only (Type 2 or Type 4 ports as describedin GR-1089-CORE, Issue 4) and require isolation from the exposedOSP cabling. The addition of Primary Protectors is not sufficientprotection in order to connect these interfaces metallically to OSPwiring.
Warning Never install telephone jacks in wet locations unless the jack isspecifically designed for wet locations. Statement 1036 Warning Never touch uninsulated telephone wires or terminals unless thetelephone line has been disconnected at the network interface.Statement 1037 Warning Class 1 laser product. Statement 1008 Ports and CablingTable 3-2 summarizes typical WAN, LAN, and voice connections forrouters. The connections summarized here are also described indetail in the document on Cisco.com: Table 3-2 WAN, LAN, and Voice Connections
Connection Procedures and Precautions
Where Do You Find The Serial Number Of A Cisco Isr 4000 Router SetupFor cable pinouts,see Cisco Modular Access Router Cable Specifications.